The Velux wind tunnel has a cross section of 7.5 x 7.5m and a length of 10.5m. The cross section of the jet blowing into the test section is 3.4 x 3.4m. The maximum flow velocity is 40m/s and the turbulence intensity at the test section inlet is 1%
The airfoil sections with a span of 1.9m and a chord of 0.6m are mounted in a test stand 1.7m above the tunnel floor and 3.2m from the nozzle outlet with end plates to limit three-dimensional flow effects. Three Pitot tubes measure static and total pressure at different locations in the test section allowing estimation of the free stream reference pressures.
The vertical span of the wake rake is 0.456m. The distance between the airfoil trailing edge and the wake rake is 0.7 airfoil chords and the centre line of the wake rake is placed at the height of the trailing edge at 0° angle of attack in the middle of the airfoil section. The wake rake is not traversed in the horizontal or the vertical directions.
Page updated 19.11.2007
Christian BakSenior ScientistWind Energy (VEA) Dir tel+45 46775091---